NEW UC INSTRUMENTS GM8042L SALES and UC INSTRUMENTS GM8042L CALIBRATION

 
Custom-Cal has for sale a new UC INSTRUMENTS GM8042L. Also, short calibration turn times minimize downtime and reasonable rates decrease your long-term cost of ownership and minimizes downtime of the UC INSTRUMENTS GM8042L. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Tunable Laser Source (TLS)?
Shop for Comparable Products on our
 used Tunable Laser Source (TLS) page or new Tunable Laser Source (TLS) page

 
List Price for a new UC INSTRUMENTS GM8042L, $11,900.00   UC INSTRUMENTS GM8042L   Description / Specification:   Spec Sheet 
UC INSTRUMENTS GM8042L L-Band Tunable Laser

The UC INSTRUMENTS GM8042L desktop tunable laser sources offer superior performance in testing DWDM components, AWG & PLC components, optical amplifiers, DWDM system and performing other general-purpose fiber optical test and measurement applications. It is a high wavelength accuracy, high power output, compact dimensions, fast startup, and affordable tunable laser source system. Specifications. Wavelength range: 1568.00 to 1610.00 nm. Output Power: >= 10 mW. Power Adjust Range: 25 dB. Wavelength resolution: 1.0 pm. Absolute wavelength accuracy: +/- 10 pm, tpy. < 5 pm. Relative wavelength accuracy: +/- 5 pm, Typ. +/- 2 pm. Wavelength repeatability: +/- 2 pm, typ. +/- 1 pm. Wavelength stability (typ., 24 hrs at constant temperature: <= +/- 2 pm. Tuning speed: <= 0.02 s per step. Power stability: < +/- 0.1 dB, 24 hours. Power repeatability: +/- 0.05 dB. Power linearity: +/- 0.3 dB. Power flatness versus wavelength: 0.3 dB typ., 0.5 dB max.. Side-mode Suppression ratio: >= 40 dBc. Relative intensity noise (RIN. Typ.): < -135 dB. Dimensions: 200 mm H, 105 mm W, 250 mm D. Weight 9.0 lbs.



 

Standard Calibration $475.00 *
*This is a Web introductory price for one calibration of the UC INSTRUMENTS GM8042L. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bit Error Ratio (BER)
Bit Error Ratio (BER) is the ratio of errors caused by the number of bits in a data stream that have been altered due to noise, interference, distoriton or bit synchronization errors.

Flatness
Variation of insertion loss on the passband of an optical device.

Polarization Dependent Loss (PDL)
Polarization Dependent Loss is the difference between the maximum and minimum values of loss due to the variation of the polarization states of light propagating through a device. PDL is expressed in decibels. Calculated by; PDL = 10 log10 (Ep/Es), where EP and ES are the measured diffraction efficiencies for P- and S-plane polarized incident light, respectively.

Return Loss (RL)
Return Loss (RL) is the ratio of the incident power to the reflected power expressed in dB. RL = 10log (Pin/Pback)

Wavelength Resolution
Wavelength Resolution is the smallest possible displayed wavelength increment/decrement.


Please contact us for your new UC INSTRUMENTS GM8042L sale price and/or UC INSTRUMENTS GM8042L CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: